One beep —
BIOS ROM checksum failure.
Possible motherboard failure
Contact Dell (see “Contacting Dell” on page 44).
Two beeps —
No RAM Detected
Remove the memory modules, reinstall
•
one module and restart the computer. If
the computer starts normally, reinstall an
additional module. Continue until you have
identified a faulty module or reinstalled all
modules without an error.
If available, install memory modules of the
•
same type in your computer.
If the problem persists, contact Dell (see
•
“Contacting Dell” on page 44).
Three beeps —
Possible motherboard failure
Contact Dell (see “Contacting Dell” on page 44).
Four beeps —
RAM Read/Write failure
Ensure that no special memory module/
•
memory connector placement requirements
exist (see the Service Manual on the Dell
Support website at support.dell.com).
Verify that the memory modules you are
•
installing are compatible with your computer.
If the problem persists, contact Dell (see
•
“Contacting Dell” on page 44).
Five beeps —
Real Time Clock Failure
Replace the battery.