Troubleshooting

This page describes a few basic troubleshooting steps to follow if problems are experienced with the Intel® AMT

configuration. Remember to always check DSN for more troubleshooting options.

Return to Default

Return to default is also known as un-provisioning. An Intel AMT setup and configured computer can be un-provisioned using

the Intel AMT Configuration screen and the Un-Provision option.

Follow the steps below to un-provision a computer:

1. Select Un-Provision and then select Full Un-provision.

Full un-provisioning is available for SMB Mode provisioned computers. This option returns all Intel AMT configuration

settings to factory defaults and does NOT reset ME configuration settings or passwords. Full and partial un-provisioning

is available for Enterprise Mode provisioned computers. Partial un-provisioning returns all Intel AMT configuration

settings to factory defaults with the exception of the PID and PPS. Partial un-provisioning does NOT reset ME

configuration settings or passwords.

An un-provisioning message displays after about 1 minute. After un-provisioning completes, control is passed back to

the Intel AMT Configuration screen. Provisioning Server, Set PID and PPS, and Set PRTC options are available

again because the computer is set to the default Enterprise Mode.

2. Select Return to previous menu.

3. Select Exit and then press .

The computer restarts.

Firmware Flash

Flash the firmware to upgrade to newer versions of Intel AMT. The automatic flash feature can be disabled by selecting

Disabled under the Secure Firmware Update setting in the MEBx interface. If this setting is disabled, a firmware error

message appears when flashing the BIOS.

The firmware CANNOT be flashed to an older version or to the current version installed. The firmware flash, when available, is

located on the support.dell.com site for download.

Serial-Over-LAN (SOL) / IDE Redirection (IDE-R)

If you cannot use IDE-R and SOL, follow these steps:

1. At the initial boot screen, press

to enter the MEBx screens.

2. When a prompt for the password appears, enter the new Intel ME password.

3. Select Intel AMT Configuration, and then press .

4. Select Un-Provision, and then press .

5. Select Full Unprovision, and then press .

6. Reconfigure the settings under the Intel AMT Configuration menu option shown

here

.

Error Message - Not able to enter the MEBx on POST

The MEBx requires the DIMM A slot to be populated otherwise the following message appears upon POST and you are unable

to enter the MEBx interface.