Statement of Volatility

– Dell Venue 11 Pro-7140

CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the
problem.

The Dell Venue 11 Pro-7140 contains both volatile and non-volatile (NV) components. Volatile components lose their data
immediately after power is removed from the component. Non-volatile (NV) components continue to retain their data even
after power is removed from the component. The following NV components are present on the Dell Venue 11 Pro-7140
system board.

Table 1. List of Non-Volatile Components on System Board

Description

Reference
Designator

Volatility Description

User
Accessible
for external
data

Remedial Action (Action
necessary to prevent loss of
data)

Embedded
controller

U3001

192 KB of embedded Flash
memory for keyboard
controller BIOS code, asset
tag and BIOS passwords

No

N/A

Panel
EEDID
EEPROM

Part of panel
assembly

Non Volatile memory, 512
bytes.

No

Part of panel assembly

System
BIOS

U2801

Non Volatile memory, 128
Mbit (16 MB), System
BIOS and Video BIOS for
basic boot operation, PSA
(on board diags), PXE
diags.

No

N/A

System
Memory –
DDR3L
memory

On board
memory

U1401,U1402,
U1501, U1502,

U1601,U1602,
U1701, U1702

Volatile memory in OFF
state

Components are all 4Gb
capacity. Total support 4GB
in system memory

Yes

Power off system

System
Memory –
LPDDR3
memory

On board
memory

U1601,U1602,
U1701, U1702

Volatile memory in OFF
state

Components are all 16Gb
capacity. Total support 8GB
in system memory

Yes

Power off system

TPM –
Trusted
Platform
Module

U6201

Discrete TPM1.2 support.
1756 bytes for user define it.

No

N/A

Hard

User
replaceable -

Sandisk / SD6SP1M-64G

Yes

Low level format