beautypg.com

Fabric management specifications, Optical port specifications, Copper gbic module – Dell PowerVault 50F (Fibre Channel Switch) User Manual

Page 28: Environmental specifications, Fabric management specifications -2, Optical port specifications -2, Copper gbic module -2, Environmental specifications -2, Table 2-2, Table 2-3

background image

2-2

Dell PowerVault 51F 8-Port Fibre Channel Switch User’s Guide

,! &

Table 2-2 shows fabric management specifications.

%

PowerVault 51F optical port interfaces use a shortwave (780 to 850 nanometer [nm])
or long wavelength (1270 to 1350 nm) laser transmitter. The laser complies with 21
CFR, subpart (J) Class 1-laser safety requirements. It uses non-open Fibre Control
(OFC) optical gigabit interface converters (GBICs) in the switch circuit. The Class 1
laser limits optical power emitted by the port to allow safe operation, eliminating the
need for physical shutters. The optical GBIC uses the duplex-SC connector scheme.

#0&

The copper GBIC module is based on the High-Speed Serial Data Connection
(HSSDC) interface standards. The GBIC provides a female HSSDC connector. Cables
of 1, 6, and 12 meters (m) have currently been qualified. Standard cables with
HSSDC-to-DB9 male connectors are also available.

'

The PowerVault 51F switch’s primary operating environments are server rooms, net-
work equipment closets, and office environments. The acceptable environmental
conditions for a PowerVault 51F switch are shown in Table 2-3.

Fabric management

Simple Name Server, Alias Server, SNMP, Telnet, World
Wide Web

User interface

RJ45 front panel connector for 10/100BASE-T Ethernet
or in-band

Maintenance port

local front panel RS-232 port for recovering defaults

!"

Temperature (operating)

0

° C to 35° C

Temperature (non-operating)

–35

° C to 65° C

Operating humidity

5% to 85% noncondensing at 40

° C

Nonoperating humidity

95% RH noncondensing at 40

° C