Ip configuration – Crestron electronic DigitalMedia Room Controller DM-RMC-100 User Manual
Page 35

Crestron DM-RMC-100
DigitalMedia™ Room Controller, CAT
IP Configuration
If the DM-RMC-100 is used in a standalone configuration (i.e. without a
DM switcher), use Crestron Toolbox to create the IP table entry for the
DM-RMC-100.
NOTE: If the DM-RMC-100 is connected directly to a DM switcher, the
IP table entry for the DM-RMC-100 is created automatically.
1. Use the Device Discovery Tool in Crestron Toolbox to find the IP
address of the DM-RMC-100. Then, display the “System Info”
window (click the icon) and select the DM-RMC-100 entry
from the Address Book.
2. Select Functions | IP Table Setup.
3. Add, modify or delete entries in the IP table. The DM-RMC-100
can have only one IP table entry.
4. A defined IP table can be saved to a file or sent to the device.
Operations & Installation Guide – DOC. 6743-1F
Room Controller, CAT: DM-RMC-100
• 31