Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

20007066

#7DVAIS
Attic Insulation
Shield

#7DVFS
Firestop in
Upper Floor

#7DVFS
Firestop in
Ceiling

Use Four
8d Nails

ST222

Fig. 33 Install firestops and attic insulation shield.

Storm
Collar

Sealant

Upper edge
of flange
goes under
upper
shingles

Flashing

#7DVSKV
(A, B, or F)
Roof Support

Use three #5
sheet metal
screws at
each joint

ST221

Fig. 34 Roof support and flashing.

8. Install appropriate pipe sections until the vent run

reaches above the flashing. The enlarged ends of
the vent sections always face downward.

9. Install the storm collar and seal around the joints. (Fig.

34)

10. Add additional vent lengths to achieve the proper

overall height.

11. Install termination cap.

Vertical Through Existing Chimney

The heater must be vented to the outdoors through an
existing masonry or prefabricated fireplace chimney
system through the roof.

The heater is approved to be vented to the outdoors
through any solid-fuel fireplace chimney that has been
constructed or installed in accordance with the na-
tional, Provincial/State and local building codes and is
constructed of noncombustible materials. For Venting
Requirements, refer to Page 10. Refer to Venting
Components on Page 12.

Fireplace Vent Termination Clearances

Observe the chimney-top vent termination clearances
specified in the instructions provided with those
components. Some considerations are:

Obstructions or impediments to venting.

Nearby combustible materials that could come into
contact with combustion exhaust gases.

Other nearby openings (within 9” (230mm) through
which exhaust gas could reenter the building.

All vegetation within 36” (914mm) that may interfere
with the draft.

NOTE: The collar extending down from the Termina-
tion base is the air intake collar. Use the flex vent liner,
marked with a blue line, to connect between this collar
and the

lower flue collar on the Transition Connector.

Also make sure the other flex vent liner is attached to the
upper Transition Connector collar and the Rain Cap. (Fig.
35)

1. Clean the top of the chimney as needed, to ensure a

good seal between it and the vent termination.

2. Slide the insulation sleeves provided in the termina-

tion kit over the two 3" flex liners (to be attached to
the 3" flue collar and cap of the termination assem-
bly).

3. Feed 3" flex vent from the bottom of the termination

assembly up through the 4" sleeve. Apply high-
temperature sealant to the rain cap collar, and slide
the flex vent over the end of the rain cap collar,
fastening with the clamp provided.

4. Slide the flex liner back through the 4" sleeve until

the rain cap/collar engages over the sleeve. Attach
the cap to the sleeve with three sheet metal screws
provided in the kit.

5. Apply high-temperature sealant over the air intake

collar, and attach the intake flex vent (blue) with a
clamp.