COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.20 on OGB 6.20 or OGS 6.20 on OGS 6.20)

SECT.

IIB

PAGE

5C

0707

by

by

Cleveland

Cleveland

Model #

Description

CSTK-620

for mounting two 6.20 models

CSTK-620CA

for mounting two 6.20 models (with casters)

UNIT A

UNIT B

2.52"

3

0

.1

2

"

5.00

"

3

0

.1

2

"

6.00

"

47.92"

1.58"

1.82"

C

7

1

.2

4

"

NOTE: Overall height of unit does not change for units with casters.

7

7

8

.0

0

(M

IN

.H

O

O

D

R

E

Q

U

IR

E

M

E

N

T

)

RC

CS

W1

W2

D

G

RC

CS

W1

W2

D

G

4.38"

39.50"

4

47.72"

4

UNIT A

UNIT A

UNIT B

UNIT B

U

LEFT SIDE VIEW

FRONT VIEW

L

6.20
on 6.20
GAS

6

RC

CS

W1

W2

D

G

38.08"

39.21"

LEFT SIDE VIEW

6.10
on 6.10
GAS

6

UNIT A

UNIT B

3

36.70"

1.58"

2

8

.4

3

5.00"

1.82"

6

7

.8

5

"

2

8

.4

3

7

8

.0

0

(M

IN

.H

O

O

D

R

E

Q

U

IR

E

M

E

N

T

)

2.52"

7

UTILITIES

(Utility connection shown below are listed per unit)

Required Clearances:

Rear - 2", Left Side - 4", Right Side - 2 1/2"

• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located

next to the unit.

• Allow for sufficient clearance on left side for service access (contact the

factory service department for recommendations).

• Installation must comply with all local fire and health codes.

Electrical Requirements:

120 volt, 60 Hz, single phase, UNIT A - 11.7 amps

Do not connect to a G.F.I. outlet.

UNIT B - 11.7 amps

Gas Connection:

3/4" NPT

Gas Type:

Natural Gas (Propane optional)

Gas Flow Pressure:

Natural Gas - Min. 5.5" WC / Max. 14" WC

Propane Gas - Min. 11" WC / Max. 14" WC

BOILER MODELS

UNIT A - OGB-6.20

UNIT B - OGB-6.20

Total Connected Load:

75,700 BTU

75,700 BTU

Steam Generator:

68,200 BTU

68,200 BTU

Hot Air:

75,700 BTU

75,700 BTU

BOILERLESS MODELS

UNIT A - OGS-6.20

UNIT B - OGS-6.20

Total Connected Load:

75,700 BTU

75,700 BTU

Hot Air:

75,700 BTU

75,700 BTU

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

Water Connections:

Cold Water (drinking water quality)

Flow Pressure:

30 - 60 PSI

Water Inlets:

3/4" GHT-F (Female Garden Hose Connection)

Treated Water for Steam Generator

Untreated Water for Condenser

Drain Connection:

2" Tube

Venting:

Exhaust Hood required

*Connection for Cleaning Solution

*Connection for Rinse Cycle

*Available as an option

Note: For additional connection details, see spec sheet for each

individual combi model to be stacked.

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

W1

W2

D

RC

S

CS

AV

G

E1

E2

This manual is related to the following products: