beautypg.com

Viewing controller settings – Contec SPI-8451-LVA User Manual

Page 59

background image

6. RAID Controller

52

SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA

12. Press [Enter] and confirm that the data will be copied on to the selected drive. All data on the

replacement drive will be written over with mirrored information from the array drive.

A progress bar will appear as below.

Please Wait While Duplicating The Image
10% Complete

13. Once the rebuild process is complete, the user will be asked to reboot the system.

Viewing Controller Settings

The Controller Configuration <6> menu selection allows you to enable or disable the RAID controller
BIOS from halting (the default) if it detects an error on boot up. You may also view the system
resources (Interrupt and I/O port address) of FastTrak’s data channels.

FastBuild (tm) Utility 1.xx (c) 1996-2001 Promise Technology, Inc.

[ Adapter Configuration - Options ]

Halt On Error:

Enable

[ System Resources Configuration ]

Channel 1 (IDE1)

Interrupt : A I/O Port : FFF0

Channel 2 (IDE2)

Interrupt : A I/O Port : FFA8

[ Keys Available ]

[

←, →, Space] Change Option [ESC] Exit

Halting RAID controller BIOS on Boot up Errors

The [Adapter Configuration – Options] section allows you to enabled or disable RAID controller to Halt
operation at the BIOS startup screen should an error be detected. This is the only option that can be
changed on this screen.

Viewing RAID Controller System Resource

The [System Resources Configurations] section of this submenu displays the PCI slot interrupt and port
address used by the RAID controller. The resources used are determined by the SPI-8451-LLVA PCI
PnP BIOS for the PCI device resides.

In the rare case that there is a resource conflict, refer to the SPI-8451-LLVA BIOS documentation on
changes on resources allocated to the RAID Controller.

This manual is related to the following products: