10

Getting Started With Your System

Power

AC power supply (per power supply)

Wattage

750 W (redundant power supply)

Voltage

100–240 VAC, autoranging, 50–60 Hz

Heat dissipation

2450 BTU/hr maximum

Maximum inrush current

Under typical line conditions and over the
entire system ambient operating range,
the inrush current may reach 55 A per
power supply for 10 ms or less

Batteries

System battery

CR 2032 3.0-V lithium coin cell

Physical

Height

8.67 cm (3.42")

Width

44.52 cm (17.53")

Depth

66.46 cm (26.17")

Weight (maximum configuration)

29.0 kg (63.8 lbs)

Weight (empty)

15.85 kg (34.87 lbs)

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, see

www.dell.com/environmental_datasheets.

Temperature

Operating

10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour

NOTE:

For altitudes above 2950 feet,

the maximum operating temperature is
derated 1ºF/550 ft.

Storage

–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation
of 20°C per hour