14
Getting Started With Your System
RAID controller module
Six single-color LEDs:
• One battery fault
• One cache active
• One controller fault
• One controller power
• One system identification
• One management Ethernet activity
Six two-color LEDs:
• Four SAS IN link or fault
• One SAS OUT link or fault
• One management Ethernet link speed
Switch
System identification button
Located on the front control panel. This button is
used to locate a system within a rack.
Enclosure mode switch
Located on the front of the system. This switch is
not applicable to the PowerVault MD3200 series
storage array.
Password reset switch
Located on the back-panel of the RAID controller
module. This switch is used to reset the storage array
password.
Power Supplies
AC power supply (per power supply)
Wattage
600 W
Voltage
100–240 VAC (8.6 A–4.3 A)
Heat dissipation
100 W
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush current
may reach a maximum of 55 A per power supply for
10 ms or less.
LED Indicators (continued)