beautypg.com

System firmware, Device firmware – Dell POWEREDGE R720 User Manual

Page 33

background image

Update Dell™ Server Hardware with Dell OpenManage Essentials

33

These are the recommendations for using the patch feature, based on the analysis of the test results:

1. Recommendation is to update not more than 30 managed systems at any given time.

2. Dell SUU is recommended as the catalog source for system update as the packages are

downloaded at a faster rate.

3. Separate system update tasks must be created for Windows and Linux targets in case of Inband

system updates.

List of System and Device Firmware and its behavior on update

System Firmware

Table 5. System Firmware Data

Type of Firmware

Reboot Required

BIOS

YES

ESM

YES

BMC

NO

Device Firmware

Table 6. Device Firmware Data

Type of Firmware

Reboot Required

PERC

YES

RAC

NO

CERC

YES

SAS

YES

SCSI BP

YES

SAS BP

NO

Storage Enclosure

NO

Zappa

NO

Pompano

YES

Tape

NO

HDD DUP

NO

Catfish

NO

Note: None of the drive update requires reboot.