Abbingdon Music Research PH-77 Reference Class User Manual
Page 18
18
4.5 Individual Default Loading
The 2
nd
line of the display displays the Load in Ohm (MC Mode, load 47 Ohm to 47KOhm) or pF (MM Mode, load
47K + 70pF to 680pF).
Use the
/
buttons on the front panel (F2) or on the remote control (RC7) to adjust the loading to that required
by the cartridge. Changes to loading happen in real-time and are applied immediately without mute. Hence, it is also
possible to optimise the loading by playing music and adjusting the load at the same time to provide the best sound
quality.
Once the desired selection has been made, press the front panel
button (F3) or on the remote control (RC6) to
confirm and continue to the next item.
It is also possible to implement a specialised, custom load. Please refer to sub-section 3.4 Loading Options for more
details.
Step 4: Loading