Air purging – FRIGIDAIRE FRS18PYS2 User Manual

Page 21

background image

Air purging with vacuum pump

1. Check that each tube(both liquid and gas side tubes) between the indoor and

outdoor units have been properly connected and all wiring for the test run has
been completed. Remove the service valve caps from both the gas and the
liquid side on the outdoor unit. Note that both the liquid and the gas side
service valves on the outdoor unit are kept closed at this stage.

2. When relocating the unit to another place, perform evacuation using vacuum

pump.

3. Pipe length and refrigerant amount:

the stopper. Do not try to open it further.

Air purging

Half union

Refrigerant

A

C

D

B

Packed valve

Gas

Indoor unit

Outdoor unit

1. Operation of opening packed valve: Open the valve stem until it hits against

2. Operation of closing packed valve: Securely tighten the valve stem with a special
tool. Then securely tighten the valve stem cap with a spanner or the like. Refer to

23

Flare nut

Stopper

Cap

Valve stem

Charge port

Valve body

Caution in handling the packed valve integrated in the outlets of

outdoor unit.

for valve stem cap tightening torque

tightening torque table in page 17

high side outlet. The low side outlet is shown in the sketch map below.

Note: There is a charging port integrated in the low side outlet, but not in the

Air

purging

Additional amount of

refrigerant to be charged

Connective

pipe length

Use vacuum pump.

Use vacuum pump.

25'~98.4

'

Less than

25'

(=18000 Btu's)

Use vacuum pump.

25'~65.6

( 12000 Btu's)

<

'

(=21500 Btu's)

R410a: 0.32ozs/ft (Pipe length-25')

R410a: 0.22ozs/ft (Pipe length-25')

R410a: 0.32ozs/ft (Pipe length-25')