beautypg.com

Electrical work – FRIGIDAIRE FRS18PYS2 User Manual

Page 18

background image

1. The inside and outside connecting

cable can be connected without
removing the front grille.

2. Connecting cable between indoor

unit and outdoor unit shall be
approved polychloroprene
sheathed flexible cord, type

cord.

3. Lift the indoor unit panel up,

remove the electrical box cover by
loosening the screw.

4. Ensure the colour of wires of

outdoor unit and the terminal Nos.
are the same to the indoors
respectively.

5. Wrap those cables not connected

with terminals with insulation
tapes, so that they will not touch
any electrical components. Secure
the cable onto the control board
with the cord clamp.

Connect the cable to the indoor unit

Electrical work

cover

Electrical box

designation 16AWG or heavier

Code wire

1.57"

0.39"

20

Terminal block of indoor unit

N(1)

2 3

To Outdoor Unit

Cable