Operating

Voltage

(Min/Max)

RLA

LRA

FLA

HP

Output

Watts

Volts

FLA

HP

Output

Watts

9K

115-1-60

ǂ

103/127

16.03

26

0.17

0.04

30

115V-AC

0.38

0.03

20

22

12K

115-1-60

ǂ

103/127

17.53

26

0.17

0.04

30

115V-AC

0.38

0.03

20

23

18K

208/230-1-60

ǂ

187/253

11.54

41

0.62

0.08

60

208/230V-AC

208/230V-AC

0.25

0.03

20

16

21.5K

208/230-1-60

ǂ

187/253

11.71

41

0.9

0.12

90

0.45

0.05

35

16

Electrical Data Table

Capacity

(BTU)

System
Voltage

Volts-Ph.-

Freq

n

a

F

r

o

o

d

n

I

n

a

F

r

o

o

d

t

u

O

r

o

s

s

e

r

p

m

o

C

MIN. Circuit

Ampacity

(MCA)

35

40

25

25

Max. Fuse/Circuit

Breaker

Amps(MOCP)

Connecting (Power and Control Cable)

The main power is supplied to the outdoor unit. The field supplied connecting cable from the outdoor unit to indoor unit consists of four

wires and provides the power for the indoor unit as well as the communication signal and ground between the outdoor and indoor unit.

Two wires are high voltage AC power, one is low voltage DC signal and one is a ground wire.

Consult local building codes, NEC (National Electrical Code) or CEC (Canadian Electrical Code) for special requirements.

Power voltage should meet the
requirements in the following
table.

3. Over current protection and circuit
disconnect should meet the
requirements in the following table
and the applicable local and national
electrical codes.