Load schedule with panel terminations, Residential lighting design guide appendix a – Crestron electronic Residential Lighting User Manual
Page 68

Residential
Lighting
Design
Guide
Appendix A
Doc. 5999F
63
Load Schedule with Panel Terminations
Project: Example Residence
Dealer: Crestron
Creator: Crestron D3 Pro v2.3.7
Description:
Date: 11/4/2003 System Number: 1
Area
Room
Controlled Ckt
Name
Controlled
Ckt No.
Fixture
Load Type
Dim Emergency
Fixture
Watts
Fixture
Qty
Total
Watts
Enclosure
Slot
Module Output
Main
Floor
Bathroom
1
Downlights 009
Downlights
Incandescent
yes
no 100
1 100
Enclosure
1
2
CLX-
1DIM8
1
Main
Floor
Bathroom
1
Downlights 2
008
Downlights Incandescent
yes
no
100
2
200
Enclosure 1
2
CLX-
1DIM8
2
Main
Floor
Bathroom
1
Downlights 3
006
Downlights Incandescent
yes
no
100
2
200
Enclosure 1
2
CLX-
1DIM8
3
Main
Floor
Bathroom
1
Drapes
019
Drapes
3-Wire Motor
no
no
200
1
200
Enclosure 1
4
CLX-
1MC4
1
Main
Floor
Bathroom
1
Exhaust Fan
007
Exhaust Fan
Switched
no
no
200
1
200
N / A
N / A Interface
2
1
Main
Floor
Bathroom
2
Downlights
011
Downlights Incandescent
yes
no
100
1
100
Enclosure 1
2
CLX-
1DIM8
4
Main
Floor
Bathroom
2
Downlights 2
010
Downlights Incandescent
yes
no
100
3
300
Enclosure 1
2
CLX-
1DIM8
5
Main
Floor
Bathroom
2
Drapes
021
Drapes
3-Wire Motor
no
no
200
1
200
Enclosure 1
4
CLX-
1MC4
2
Main
Floor
Bathroom
2
Exhaust Fan
012
Exhaust Fan
Switched
no
no
200
1
200
N / A
N / A Interface
4
1
Main
Floor
Bedroom
Ceiling Fan
022
Ceiling Fan
Ceiling Fan
no
no
100
1
100
Enclosure 1
6
CLX-
1FAN4
1
Main
Floor
Bedroom Downlights
005 Downlights
Incandescent
yes no 250 2 500
Enclosure
1
2 CLX-
1DIM8
7
Main
Floor
Bedroom
Downlights 2
004
Downlights Incandescent
yes
no
100
4
400
Enclosure 1
3
CLX-
1DIM4
1
Main
Floor
Bedroom Downlights
3
003 Downlights
Incandescent
yes
no
100
1
100
N / A
N / A Interface
6
1
Main
Floor
Bedroom
Downlights 4
002
Downlights Incandescent
yes
no
100
1
100
N / A
N / A Interface
5
1
Main
Floor
Bedroom
Downlights 5
001
Downlights Incandescent
yes
no
100
2
200
Enclosure 1
3
CLX-
1DIM4
2
Main
Floor
Bedroom
Drapes
018
Drapes
3-Wire Motor
no
no
200
1
200
Enclosure 1
4
CLX-
1MC4
3
Main
Floor
Bedroom
Drapes 2
017
Drapes
3-Wire Motor
no
no
200
1
200
Enclosure 1
4
CLX-
1MC4
4
Main
Floor
Bedroom
Drapes 3
016
Drapes
3-Wire Motor
no
no
200
1
200
Enclosure 1
5
CLX-
1MC4
1
Main
Floor
Foyer Downlights 013 Downlights
Incandescent
yes no 100 4 400
Enclosure
1
2 CLX-
1DIM8
6
Main
Floor
Sauna
Drapes
020
Drapes
3-Wire Motor
no
no
200
1
200
Enclosure 1
5
CLX-
1MC4
2
*Calculation of load wattage includes transformer loss.
The following three pages contain the complete application diagrams of this example
system, Circuits and Interfaces, Module Wiring, and PAC2 Connections, divided up to
fit the space available. The complete diagram is available on line at:
http://www.crestron.com/dealer-tech_resources/application_diagrams.asp
.