4.2.3. Read current value and key status, command „T“ (54h)
This command is for readout the 6-digit current value (bottom line of the display) as well as the key status.
Amount of data is always 7 byte. Negative values will come with a “-“ sign (2Dh) together with 5 data bytes.
Positive values are transmitted by 6 data bytes less any sign. Values inferior to 6 (5) digits come with preceding
zeroes. The 7
th
data byte is comprising the key status. A readout operation is deleting the status of the actuated
key (21hex) so that any further readout will always be 20hex. Status 1 (21hex) will not be restored until the key
is actuated again.
Example: Current value = -32,50
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
20h
54h
04h
40h
SOH
Adr
Cmd
Current value = –32,50
key
EOT
CRC
Response
key = 0
01h
20h
54h
2Dh
30h
33h
32h
35h
30h
20h
04h
E2h
SOH
Adr
Cmd
Current value = –32,50
key
EOT
CRC
Response
key = 1
01h
20h
54h
2Dh
30h
33h
32h
35h
30h
21h
04h
E0h
4.2.4. Read / write parameter target (profile), command „S“ (53h)
This command is for the presently active target readout or for programming respectively reading a specific
target. The data are composed of profile number (2 bytes) and target (6 bytes). Important: Negative targets
come with 5 digits only (see example no. 3).
Example 1: Read active target (current profile number = 12; target = 12,50)
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
20h
53h
04h
2A
SOH
Adr
Cmd Profile no. = 12
Target = 12,50
EOT
CRC
Response
01h
20h
53h
31h
32
30h
30h
31h
32h
35h
30h
04h
3E
Response upon deletion of all targets:
SOH
Adr
Cmd
Profile no. =
FFh
Target = FFFFFFh
EOT
CRC
Response
01h
20h
53h
3Fh
3F
3Fh
3Fh
3Fh
3Fh
3Fh
3Fh
04h
2Ah
Example 2: Read target of a specific profile (profile number = 17; target = 12,50)
SOH
Adr
Cmd Profile no. = 17 EOT
CRC
Transmission
01h
20h
53h
31h
37h
04h
16h
SOH
Adr
Cmd Profile no. = 17
Target = 12,50
EOT
CRC
Response
01h
20h
53h
31h
37h
30h
30h
31h
32h
35h
30h
04h
BCh
Example 3: Write target of a specific profile (profile number = 17; target = -12,50)
s
SOH
Adr
Cmd Profile no. = 17
Target = -12,50
EOT
CRC
Transmission
01h
20h
53h
31h
37h
2Dh
30h
31h
32h
35h
30h
04h
FBh
SOH
Adr
Cmd Profile no. = 17
Target = -12,50
EOT
CRC
Response
01h
20h
53h
31h
37h
2Dh
30h
31h
32h
35h
30h
04h
FBh
s