N 141 – Baumer N 141 User Manual
Page 13
![background image](/manuals/605581/13/background.png)
N 141
www.baumer.com
13
Turn display
This parameter turns the display by 180°.
0 = Off
Display readout with standard mounting, i.e. display above keypad
1 = On
Display readout with inverted mounting, i.e. display below keypad
Offset
Command „U“ is for programming the offset that is added to the current value and current target. This parameter
defines whether the offset is considered in the calculation.
Parameter 2 means optional manual offset alteration directly at the device itself. Press both softkeys at the same
time and proceed offset alteration by turning the shaft. Press the softkeys anew to quit. The bottom line shows
the unchanged current value again. The value alteration emerging from the shaft turn has been assigned to the
offset.
0 = Off
Offset disabled. The previous offset transmitted -if any- is neither added to current value nor
target
1 = SER
Offset enabled. Offset is added to the actual current value.
Offset alteration by serial interface
2 = S+K
Offset enabled. The offset is added to the actual current value.
Offset alteration either by serial interface or manually at the device.
Hide target
This parameter defines when to indicate the target in the upper line of the display.
0 = On
Ever indicate target if target ≠ current value
1 = Off
Ever indicate target, even if target = current value. Indicate also arrows if target ≠ current value.
2 = Ever
Ever hide both target and arrows.
4.3.2. Read /write parameter spindle tolerance and tolerance window, command „b“ (62h)
This command is for reading or writing the parameters tolerance compensation and tolerance window.
Example 1: Read parameter (tolerance compensation = 0,15; tolerance window = 0,25)
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
20h
62h
04h
48h
SOH
Adr
Cmd Tolerance compensation=0,15
Tolerance window=0,25
EOT
CRC
Response
01h
20h
62h
30h
30h
31h
35h
30h
30h
32h
35h
04h
AAh
Example 2: Write parameter (tolerance compensation = 1,30; tolerance window = 5,00)
SOH
Adr
Cmd Tolerance compensation=1,30
Tolerance window=5,00
EOT
CRC
Transmission
01h
20h
62h
30h
31h
33h
30h
30h
35h
30h
30h
04h
20h
SOH
Adr
Cmd Tolerance compensation =1,30
Tolerance window=5,00
EOT
CRC
Response
01h
20h
62h
30h
31h
33h
30h
30h
35h
30h
30h
04h
20h