5085A751
5080A751
• Rating (BTU/Hr)
80,000 to 200,000
30,000 to 80,000
• Fuel
Propane Vapor Only
Propane Vapor Only
• Fuel Consumption
Gallons/Hour
0.9 minimum/2.2 maximum
0.3 minimum/0.9 maximum
Pounds/Hour
3.8 minimum/9.3 maximum
1.4 minimum/3.8 maximum
• Supply Pressure (To Regulator)
Maximum
Tank Pressure
Tank Pressure
Minimum, for input adjustment
24 psi
24 psi
• Regulator Outlet Pressure
10 psi
10 psi
• Weight (Pounds)
14.7
12.24
• Size (Inches)
28
3
/
4
x 13
1
/
4
diameter
21 x 13
1
/
4
diameter
• Minimum Ambient
Temperature for use
0
°
F
0
°
F
• Shipping Dimensions (Inches)
29
1
/
2
x 14
1
/
8 X
14
1
/
8
21
3
/
4
x 14
1
/
8 X
14
1
/
8
• Shipping Weight (Pounds)
17
14.1
If you have questions, contact Coleman at 1-800-835-3278 or TDD: 316-832-8707.
I.D.
PART NO.
DESCRIPTION
NO.
1
5080-3111
Electronic Ignition Assembly
2
5080-1491
Knob and Screw
3
5080-5651
Hose and Regulator Assembly
4
5080-2181
Gas Tip (for 5080A Heater)
5085-2181
Gas Tip (for 5085A Heater)
5
5080-3271
Thermocouple and Clip
6
5080-1151
Top Cap and Screws
7
5410A1381
O-ring
1
2
3
4
5
6
7