Specifications & Performance Claims

Model EP 7130

Model EP 7140

Model Code

E7130

E7140

Rated Softening Capacity (Grains @ Salt Dose)

14,700 @ 2.9 lbs.

25,400 @ 8.0 lbs.

30,100 @ 13.1 lbs.

11,900 @ 2.4 lbs.

31,800 @ 9.1 lbs.

40,400 @ 15.8 lbs.

Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose)

5,060 @ 2.9 lbs.

4,960 @ 2.4 lbs.

Water Used During Regeneration @ Minimum Salt Dose

2.3 gal. / 1,000 grains

3.4 gal. / 1,000 grains

Total Water Used Per Regeneration @ Maximum Salt Dose

35.2 gallons

41.6 gallons

Rated Service Flow Rate

7.5 gpm

9 gpm

Amount of High Capacity Ion Exchange Resin

.82 cu. ft.

1.16 cu. ft.

Pressure Drop at Rated Service Flow

13.4 psig

9.1 psig

Water Supply Max. Hardness

110 gpg

110 gpg

Water Supply Max. Clear Water Iron

8 ppm*

10 ppm*

Water Supply Pressure Limits (minimum / maximum)

20 - 125 psi (137.9 - 861.8 kPa)**

Water Temperature Limits (minimum / maximum)

40 - 120 °F

Minimum Water Supply Flow Rate

3 gpm

Maximum Drain Flow Rate

2.0 gpm

Salt Storage Capacity

220 lbs.

Questions? Call Toll Free 1-800-693-1138

Monday- Friday, 7 AM - 6 PM CST

or visit www.ecopurewaterproducts.com

When you call, please be prepared to provide the model and serial number,

found on the rating decal, typically located on the rim below the salt lid hinges.

*

Capacity to reduce clear water iron is substantiated by WQA test data. State of Wisconsin requires additional

treatment if water supply contains clear water iron exceeding 5 ppm.

**Canada working pressure limits: 1.4 - 7.0 kg/cm

2

.

These systems conform to NSF/ANSI 44 for the specific performance claims as verified and substantiated by

test data.
Variable Salt Dose: The salt dose is selected by the electronic controls at regeneration time based on the

amount needed.

These models are efficiency rated. The efficiency rating is valid only at the minimum salt dose. These softeners

have a demand initiated regeneration (D.I.R.) feature that complies with specific performance specifications intended

to minimize the amount of regenerant brine and water used in their operation.
These softeners have a rated softener efficiency of not less than 3,350 grains of total hardness exchange per pound

of salt (based on sodium chloride) and shall not deliver more salt than their listed rating or be operated at a sus-

tained maximum service flow rate greater than their listed rating. These softeners have been proven to deliver soft

water for at least ten continuous minutes at the rated service flow rate. The rated salt efficiency is measured by lab-

oratory tests described in NSF/ANSI Standard 44. These tests represent the maximum possible efficiency that the

system can achieve. Operational efficiency is the actual efficiency after the system has been installed. It is typically

less than the rated efficiency, due to individual application factors including water hardness, water usage, and other

contaminants that reduce a softener's capacity.