Routine Maintenance

PROTECT THE WATER SOFTENER FROM

FREEZING

If the softener is installed where it could freeze (sum-

mer cabin, lake home, etc.), you must drain all water

from it to stop possible freeze damage. To drain the

softener:
1. Close the shut-off valve on the house main water

pipe, near the water meter or pressure tank.

2. Open a faucet in the soft water pipes to vent pres-

sure in the softener.

3. Move the stem in the single bypass valve to

bypass. Close the inlet and outlet valve in a 3

valve bypass system, and open the bypass valve.

If you want water in the house pipes again, reopen

the shut-off valve on the main water pipe.

4. Unplug the transformer at the wall outlet. Slide

open the salt lid and remove the softener’s top

cover. Take off both drain hoses if they will inter-

fere with moving the softener into position over the

drain.

5. Carefully remove the large holding clips at the sof-

tener inlet and outlet. Separate the softener from

the plastic installation adaptors, or from the bypass

valve.

6. Lay a piece of 2 inch thick board near the floor

drain (See Figure 28).

7. Move the softener close to the drain. Slowly and

gently, tip it over until the rim rests on the wood

block with the inlet and outlet over the drain. Do

not allow the softener’s weight to rest on the inlet

and outlet fittings or they may break.

8. Tip the bottom of the softener up a few inches and

hold until all water has drained. Leave the softener

laying like this until you are ready to use it. Plug

the inlet and outlet with clean rags to keep dirt,

bugs, etc. out.