Dynalco DYNA-GEN Flywheel Generator System User Manual
Page 5

Terminal Connections
Wiring:
Power Coil: The (4) wires on the power coil are color coded and must be connected to the 4-
terminal block (J1) of the Power Supply Module as indicated. The wiring between the Power Coil
and Power Supply Module must be run in conduit for protection.
Power Supply Module: The 12 VDC output from the Power Supply Module is available from (2)
outputs. The “Main” output provides up to 6 Amps output for powering the engine panel as well as
providing charging current to the battery. The “Ignition” output provides up to 2 Amps output for
powering the ignition system. All output connections are to be made on the 6-terminal block (J2)
as indicated. All wiring should be with AWG 16 minimum wire gage.
5