Technical data, Ambient conditions camera housing – Colorlight CLIR User Manual
Page 6

Page 6
CL
IR
MANUAL
Technical data
Weight (additional on searchlight) 2,1 kg
Static size thermal module
15x15x20 cm
Material housing
Acid proof stainless steel 1.4401
Paint housing
Powder coat white RAL9016 as standard
Frontwindow material
Germanium
Frontwindow heater/ Deicer
Rated Power
Supply
Switch-on temperature
Etched Polyimide foil heater with temperature controller
~10W
24Vdc supplied from electric box
+12C or bellow
Ambient conditions Camera housing
Enclosure rating of the housing
IP66
Operating temperature
-40°C to +80°C
Storage temperature
-50°C to +85°C
Thermal Shock
No damage or permanent degradation after extreme
thermal shock from one extreme of the operating
temperature range to the other.
Mechanical Shock
No damage or permanent degradation after exposure to
shock pulses of 250 g (1.5msec half-sine) and 500g
(0.8msec halfsine) along any axis.
Vibration
Meets all requirements of this specification and exhibits no
damage or permanent degradation after exposure to
random vibration along any axis up to 4.3 grms per the
profile specified below.
Frequency
(Hz)
Acceleration
Density (G2/Hz)
10
0.040
20
0.100
100
0.100
800
0.002
1000
0.002
Altitude
Meets all requirements of this specification and exhibits no
damage or permanent degradation after exposure to
pressure equivalent to 12 km above sea level.