beautypg.com

0 dimensions – Cooper Instruments & Systems LXT 971 Rotating Torque Load Cell User Manual

Page 2

background image

CF 59 

Rev. I  September 2013

 

10 

Output resistance 

Ω 

50 

 

Effect of Temperature 

Unit 

Value 

11  

Zero point drift over temperature 

%/10K 

<1.0 

12 

Signal drift over temperature within 
nominal temperature range

2

 

%/10K 

<1.0 

 

Power Supply 

Unit 

Value 

13 

Supply voltage 

VDC 

9…12 

14 

Current Consumption (max.) 

mA 

10 

15 

Start‐up peak 

mA 

<40 

16 

Absolute max. supply voltage 

VDC 

13 

 

General Information 

Unit 

Value 

17 

Degree of protection acc. to EN 60529 

IP 

50 

18 

Reference temperature 

°

+15…+35 

19 

Operational temperature range 

°

C

‐30…+85 

20 

Storage temperature range 

°

C

‐30…+100 

 

Nominal rated torque M (bi‐directional) 

Nm

2.5 

5.0 

7.5 

17.5 

75 

175 

250 

500 

21 

Weight 

Rd

g

386 

392 

400 

685 

856 

1230 

Sq

395 

401 

414 

652 

754 

878 

22 

Moment of inertia 

Rd

g

mm

2

597 

662 

1073 

4922 

19126 

79754 

Sq

582 

648 

904 

3339 

13294 

57770 

  

%ME: related to a full scale measurement range 

1) The accuracy class implies that taken separately both the linearity deviation as well as the rotational signal uniformity is 

either lower than or equal to the value of the accuracy class. The accuracy class is not to be identified with the classification 
following DIN 51309 or EA‐10/14. 

2) The factor of transmission declines linearly up to a maximum of 0.5% / 10K with rising temperature, due to the reduction of 

the elasticity.  

4.0 Dimensions

 

 

 

 

 

 

 

 

 

 

 

(1) Do not loosen or tighten the mounting nuts of
the socket and the lock screws.

LXT 971 

(Round Drive)

LXT 970 

(Square Drive)