0 dimensions – Cooper Instruments & Systems LXT 971 Rotating Torque Load Cell User Manual
Page 2
![background image](/manuals/600677/2/background.png)
CF 59
2
Rev. I September 2013
10
Output resistance
Ω
50
Effect of Temperature
Unit
Value
11
Zero point drift over temperature
%/10K
<1.0
12
Signal drift over temperature within
nominal temperature range
2
%/10K
<1.0
Power Supply
Unit
Value
13
Supply voltage
VDC
9…12
14
Current Consumption (max.)
mA
10
15
Start‐up peak
mA
<40
16
Absolute max. supply voltage
VDC
13
General Information
Unit
Value
17
Degree of protection acc. to EN 60529
IP
50
18
Reference temperature
°
C
+15…+35
19
Operational temperature range
°
C
‐30…+85
20
Storage temperature range
°
C
‐30…+100
Nominal rated torque M (bi‐directional)
Nm
2.5
5.0
7.5
17.5
75
175
250
500
21
Weight
Rd
g
386
392
400
685
856
1230
Sq
395
401
414
652
754
878
22
Moment of inertia
Rd
g
mm
2
597
662
1073
4922
19126
79754
Sq
582
648
904
3339
13294
57770
%ME: related to a full scale measurement range
1) The accuracy class implies that taken separately both the linearity deviation as well as the rotational signal uniformity is
either lower than or equal to the value of the accuracy class. The accuracy class is not to be identified with the classification
following DIN 51309 or EA‐10/14.
2) The factor of transmission declines linearly up to a maximum of 0.5% / 10K with rising temperature, due to the reduction of
the elasticity.
4.0 Dimensions
(1) Do not loosen or tighten the mounting nuts of
the socket and the lock screws.
LXT 971
(Round Drive)
LXT 970
(Square Drive)