Troubleshooting, 14 troubleshooting – B&G Triton Display User Manual
Page 16
![background image](/manuals/599951/16/background.png)
14 |
Troubleshooting |
IS40/Triton System Installation Manual
Troubleshooting
Issue
Solution
Unit does not power
up
•
Check that the NMEA 2000/SimNet
network has 12 V connected.
•
Try connecting to a different network
cable in case power wires damaged
internally.
Unit does not show
data for a specific
source
•
In the advanced setup menu, select
sources, and manually select the
required data source.
•
Check the network connection on the
data source.
Unit does not show
any data from any
connected source
or
Unit data sources
intermittently drop
out.
•
In the advanced setup menu, select
sources option, then select AUTO
SELECT.
•
Check the Device List menu and see if
any devices are detected.
•
Try connecting to a different network
cable in case data wires damaged
internally.
•
In the advanced setup menu, check
the diagnostics page to see if any
errors are occurring.
•
Check network topology and
termination rules are correctly
implemented.
•
Disconnect other devices from
network, one-by-one, starting with
3rd party devices.