188

Press encoder in and then rotate clockwise for more contrast,

counter-clockwise for less contrast.

Contrast Adjust

The Net Number identifies the particular unit within a system.

Note: There must be only one unit assigned to one Net Number

otherwise the Remote Control and metering will be unpredict

-

able.

Net Number

DHCP requires a router which will ‘serve’ an IP address dynamically. Fixed IP forces the address

that is programmed into the unit and modified by the Net Number. The letter ‘D’ will be in front of

the IP address when DHCP is selected and the letter ‘F’ will be in front of the IP address when Fixed

IP is selected. The fixed IP addresses range from 192.168.1.64 for Net Number 001 to 192.168.1.192

for Net Number 128. If these addresses are not compatible with your network, please contact Aphex.

Note: Power must be cycled off and on to commit these changes.