AC Power Draw and Thermal Dissipation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Data based on all channels driven.
Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Line current figures for 100VAC units (not shown) are 1.2 times the line current figures of 120VAC units.
Power draw (”watts in”) of 100VAC units is the same as power draw of 120VAC units.

watts in

watts out

dissapated

Btu/hr

kcal/hr

At Idle (sleep mode)

40

0

40

137

34

1/8th Power Pink Noise

8 Ohms/Ch.

1000x2

Typical of program material

16 Ohms Bridge

2000

just at clip.

4 Ohms/Ch.

1000x2

8 Ohms Bridge

2000

2 Ohms/Ch.

1000x2

4 Ohms Bridge

2000

70/100V/Ch.

1000x2

140/200V Bridge

2000

1/3rd Power Pink Noise

8 Ohms/Ch.

1250x2

Typical of program material

16 Ohms Bridge

2500

with severe clipping.

4 Ohms/Ch.

1500x2

8 Ohms Bridge

3000

2 Ohms/Ch.

1500x2

4 Ohms Bridge

3000

70/100V/Ch.

1500x2

140/200V Bridge

3000

CTs 3000

Load

Rated

Power

Line Current

120VAC

Line Current

230VAC

Watts

Thermal Dissipation

7.2

3.6

579

313

266

907

229

8.5

4.2

697

381

316

1079

272

9.6

4.8

790

384

405

1384

349

7.2

3.6

579

313

266

907

229

13.7

6.8

1196

835

360

1230

310

16.2

8.1

1469

1010

459

1565

395

19.2

9.6

1686

1024

662

2259

570

13.7

6.8

1196

835

360

1230

310

8 AC Power Draw and Thermal Dissipation