Primelog – ADS Environmental Services PrimeLog QR 775015 A0 User Manual
Page 12

ADS PrimeLog User Manual
8
PrimeLog
PrimeLog submersible data loggers are available with one to four input 
channels and various power options. An internal pressure transducer is 
available with all models. The tables in the Introduction outline the range of 
loggers and features available. This section offers additional information and 
details for the various logger types. 
All loggers are equipped with military-grade connectors and are sealed 
according to IP68 specifications. 
PrimeLog (Model 2)
A serial connection provides local communication with a PC/laptop computer, 
which may include a display for taking measurements real-time and viewing 
stored data. 
The PC/laptop-based PrimeWorks
®
host application provides comprehensive
software support. This multi-task system, running on a Microsoft
®
Windows
®
95, 98, Me, NT, 2000, or XP operating system, supports local loggers. 
PrimeWorks incorporates advanced graphing and reporting through Wizards 
to dramatically simplify data presentation. The graphical user interface 
includes full drag-and-drop capabilities and dockable toolbars. Refer to the 
ADS PrimeWorks
®
User Manual (QR 775018 A*) for more information.
PrimeLog units are powered by an internal battery with an optimal battery life 
of 5 years or more, based on the nature of use. However, please note that 
temperature can affect battery life significantly. Operating the unit continually 
above 86
°F (30°C) or below 32°F (0°C) will reduce battery life.