Parameter settings – Great Plains ADC1150 Operator Manual User Manual
Page 43

41
Section 4 System Monitor
6/15/05
ADC1150 Air Drill Cart 167-101M
Great Plains Mfg., Inc.
NOTE: Optional blockage sensors come in 2 varieties; Pin
sensors and Optical sensors. The blockage module pack-
age included with your system will identify the style of sen-
sor supplied.
Pin blockage sensors do not need to be disconnected and
will not be requested during initial monitor setup. If system
is equipped with pin style blockage sensors press the ACK
button to skip FLOW 1-7. The blockage module package
includes installation instructions.
When optical blockage sensors have been supplied, you
must plug the 3-pin connector of the blockage module in
order as requested by the module; FLOW 1-7. The Optical
blockage sensors may be plugged into the proper 2-pin
blockage harness connection during initial setup.
d.
When you have completed sensor installation, re-
fer to Set Parameter Levels below. All parameters
must be set before the unit is ready to use.
3. Set Parameter Levels
You can adjust alarm trip points, sensor configurations
and other system features. You must reset these parame-
ters when you initially set up the system. You can re-adjust
the parameters later. Parameter settings are stored in
monitor memory even when monitor power is shut off.
a.
Choose the function you wish to program by
pressing the up and down buttons until desired
function is displayed on the monitor readout.
b.
Hold MODE button to enter programming mode.
c.
Use the MODE button to switch between the pa-
rameters. Each function has several parameters
which can be adjusted. The top display indicates
which parameter is being adjusted. The lower dis-
play indicates how the parameter is currently set.
d.
Use the following chart to program the parame-
ters. The chart lists the parameters for each func-
tion and proper parameter settings.
e.
Use the up and down buttons to increase or de-
crease the parameter level to the proper setting.
NOTE: To disable a function, set the pulse level to zero.
The system will not monitor disabled functions.
f.
When you have properly set all parameters for the
function, press MODE button until “SAVE” is on
the top display.
g.
Press the up button to choose yes (Y) if you wish
to save your settings. Press the down button to
choose no (N).
h.
Hold down the ACK button. If yes was chosen, the
unit will beep five times before saving the settings.
i.
Repeat steps a. through h. for each function until
all parameters have been set.
Parameter Settings
Function Monitored
Parameters
As Displayed on Monitor
Proper Setting
Parameter Description
Parameter Range
Ground Speed
PPM
30-ft. drill: 2865
34-ft. drill: 3248
35-ft. drill: 3248
40-ft. drill: 3755
45-ft. drill: 4255
Pulses per mile
500 to 9999
Fan Speed
PULSES
3
Hits per revolution
1 to 10
LO FAN
2000
Low rpm alarm point
1000 to 9900
HI FAN
5000
High rpm alarm point
low alarm to 9900
Front Metering Shaft
PULSES
2
Hits per revolution
0 to 4
Rear Metering Shaft
PULSES
Zero
Hits per revolution
0 to 4
Bin Level
LEVEL
20%
Low bin alarm point
0 to 100%
Field and Total Area
Set WIDTH and UNITS for
both functions.
WIDTH
Implement width
Implement width
0 to 99 ft.
UNITS
Operator preference
Units values are displayed in
English or Metric
Flow (
Pin Sensors)
BOXES
Proper setting is the
total number of
modules attached.
Number of blockage modules-
may not be one per tower, often
is not.
3 to 7
TYPE
Zero
0 to 63
Flow
(Optical Sensors)
INSTALL “Y”
Proper setting is the
total number of
sensors attached to
each module
Number of sensors per module
3 to 7
INSTALL “N”
Operator Preference
Turns row sensors “on” and
“off”
ON or OFF