1.

Connect auger/fold hoses. Auger/fold hoses go to the
diverter valve on the inside of the left tongue rail.

2.

Connect lift hoses. Lift hoses are the 3/8-inch hoses
that go directly to the lift couplers on rear of cart.

3.

Connect fan hoses. If your tractor has a priority circuit
for hydraulic motors, connect hoses to this circuit.

a.

Hook 1/2-inch hose (1) shown in Figure 1-6 to the
outlet you choose to be the pressure side of cir-
cuit.

b.

Hook 3/8-inch hose to other outlet.

NOTE: Fan hoses are not the same size. A 1/2-inch and a
3/8-inch hose are paired together.

Figure 1-6

Hydraulic Hook-Up for Older Carts with ADI

c.

Connect 1/2-inch sump hose (2) shown in Figure
1-6
to the tractor hydraulic reservoir. Refer to your
tractor operator’s manual for instructions.

NOTE: For proper hydraulic flow, use a poppet-style, Pio-
neer quick coupler to connect sump hose to tractor. See
Figure 1-4.