Great Plains Fertilizer Arm Kits User Manual
Page 11
![background image](/manuals/598819/11/background.png)
7/31/2002
204-326M
9
NOTE: When using a squeeze pump, use a H1/4U-SS0040 nozzle and disregard rate charts. The squeeze pump
controls the rate of application.
Teejet
Equiv.
CAPACITY
Capacity
Spray
Orifice
{gallons per minute}
Size
Angle
Diam.
Desig-
Inches
5
10
20
30
40
60
80
100
200
300
nation
psi
psi
psi
psi
psi
psi
psi
psi
psi
psi
000009
0˚
.008
.003
.005
.006
.008
.009
.011
.013
.014
.020
.025
000012
0˚
.010
.004
.006
.008
.01
.012
.015
.017
.019
.027
.033
000019
0˚
.012
.007
.009
.013
.016
.019
.023
.02
.03
.043
.062
000021
0˚
.0135
.007
.01
.015
.018
.021
.026
.03
.033
.047
.058
000050
0˚
.020
.018
.025
.035
.043
.050
.06
.07
.08
.11
.14
000067
0˚
.023
.024
.033
.05
.06
.067
.08
.09
.11
.15
.18
0001
0˚
.028
.035
.05
.07
09
.10
.12
.14
.16
.22
.27
00015
0˚
.033
.05
.07
.11
.13
.15
.18
.21
.24
.34
.41
0002
0˚
.039
.07
.10
.14
.17
.20
.25
.28
.32
.45
.55
0003
0˚
.047
.10
.15
.21
.26
.30
.37
.42
.47
.67
.82
0004
0˚
.055
.14
.20
.28
.335
.40
.49
.57
.63
.89
1.1
0005
0˚
.061
.18
.25
.35
.43
.50
.61
.71
.79
1.1
1.4
0006
0˚
.067
.21
.30
.42
.52
.60
.73
.85
.95
1.3
1.6
0008
0˚
.078
.28
.40
.56
.69
.80
.98
1.1
1.3
1.8
2.2
0010
0˚
.086
.35
.50
.71
.86
1.0
1.2
1.4
4.6
2.2
2.7
0015
0˚
.107
.53
.75
1.1
1.3
1.5
1.8
2.1
2.4
3.4
4.1
0020
0˚
.125
.71
1.0
1.4
1.7
2.0
2.5
2.8
3.2
4.5
5.5
0030
0˚
9/64
1.1
1.5
2.1
2.6
3.0
3.7
4.2
4.7
6.7
8.2
0040
0˚
5/32
1.4
2.0
2.8
3.5
4.0
4.9
5.7
6.3
9.0
11.0
0050
0˚
11/64
1.8
2.5
3.5
4.3
5.0
6.1
7.1
7.9
11.2
13.7
0060
0˚
3/16
2.1
3.0
4.2
5.2
6.0
7.3
8.5
9.5
13.4
16.4
0070
0˚
13/64
2.5
3.5
4.9
6.1
7.0
8.6
9.9
11.1
15.7
19.2
0080
0˚
13/64
2.8
4.0
5.6
6.9
8.0
938
113
12.6
17.9
22.0
00100
0˚
15/64
3.5
5.0
7.1
8.6
10.0
12.2
14.1
15.8
22.0
27.0
00120
0˚
1/4
4.2
6.0
8.5
10.4
12.0
14.7
17.0
19.0
27.0
33.0
00150
0˚
19/64
5.3
7.5
10.6
13.0
15.0
18.4
21.0
34.0
34.0
41.0
00200
0˚
21/64
7.1
10.0
14.1
17.3
20.0
25.0
28.0
32.0
44.0
55.0
00250
0˚
3/8
8.8
12.5
17.7
22.0
25.0
31.0
35.0
40.0
56.0
68.0