beautypg.com

Great Plains NH3 Safety User Manual

Page 38

background image

34

NH

3

Safety

Table of Contents

Index

Great Plains Manufacturing, Inc.

407-551M

Table of Contents

Index

2013-07-15

11. Opening this bleed valve WILL release the

substantial amount of liquid NH

3

presently trapped in

the hose, most likely as a spray. Open the valve very
slowly, just until some fluid appears. Leave the valve
just slightly open.

12. Walk away, up-wind. Stay away until the release

concludes. Carefully open bleed valve completely to
confirm hose is discharged. For dual-cooler, repeat
step 9 through step 12 for the other hose.

13. Close all breakaway bleed

valves (

and

{page 42}), and any nurse tank

hose valves

(page 13). Disconnect the nurse

tank half of the breakaway coupler at the Acme
coupler

(page 11).

14. Correct the cause of breakaway, only if trivial to do in

the field.

15. Consult the breakaway manual for re-coupling

instructions.

Before Re-connection: Elevated Exposure Hazard:
Exercise extreme care. Even if the nurse tank is undamaged,
sound and upright, a breakaway event is not a normal re-hitch
situation. A substantial NH

3

bleed is required that WILL

release a flow of liquid anhydrous ammonia under pressure.
If the wind is calm or light, do not attempt to bleed the nurse
tank hose.
Your field PPE

a

is not sufficient.

a. PPE: Personal Protective Equipment

A13

A16

A61

A58