beautypg.com

Finger meter adjustments, Finger meter brush adjustment – Great Plains YP1625 Material Rate User Manual

Page 36

background image

Great Plains Mfg., Inc.

32

401-263B

11/23/2011

Finger Meter Adjustments

The finger pick up meter has an adjustable brush, and
alternate inserts are available for the backing plate. The
factory-installed insert is the “A” insert.

Optimum planting speed is 4

1

2

to 5 mph (7 to 8 kph).

Excess speed results in poor spacing performance due
to seed tube bounce. Excess speed may also result in
improper depth control due to row unit bounce.

Always pay attention to your planter monitor. Compare
actual seed usage to your estimates.

Fine-tune your planter by thoroughly checking all key
components including: seed tubes, chains, sprockets,
tire pressure, seed monitor, double disk openers, gauge
wheels, seed firmer, closing wheels, parallel arms, and
the row unit itself.

Finger Meter Brush Adjustment
The brush reduces or eliminates “doubles” (delivering
two seeds per finger), but if set too aggressively can
cause “skips” (delivering no seed on some fingers). As
needed, adjust for minimal doubles and skips.

Note: These instructions describe the current finger pick-

up meter shipped with new Great Plains planters,
which has an integrated adjustment lever for the
brush. If you have the previous model meters, ad-
justed by screwdriver rather than lever, rely on
counting detents to determine the setting. Not all
have 9 detents.

Refer to Figure 10
The adjustable brush provides additional flexibility to
accommodate a wide range of seed sizes. Use lever (L)
to gently rotate the brush into position.

The settings range from 1 to 5 with detents at each half
step, for a total of 9 detents. Although the numbers are
molded into the meter housing, only “1” and “5” may be
visible.To ensure consistency, rotate the lever fully
counter-clockwise (1), and count detents as you advance
it to the desired setting.

Use the general guidelines in the table below to adjust
the brush position to your seed size and shape. The
numbers listed correspond to the numbers printed on the
outer housing of your meter. If there is a decal on your
meter, its units are seed size in pounds per 80,000 seed
bag. The table below includes seeds per kg and pound.

Null4-AAC:

Figure 10

Finger Meter Brush Lever

25276

5

1

4

3

2

L

Bag Weight

Seeds Per

Brush

Seeds Per

Bag Weight

(80,000 seeds)

Pound

Setting

Kilogram

(80,000 seeds)

Rounds

65 lbs

1230 or less

1

2710 or less

29.5 kg

65 to 55 lbs

1230 to 1450

2

2710 to 3195

29.5 to 24.9 kg

55 to 45 lbs

1450 to 1780

3

3195 to 3925

24.9 to 20.4 kg

45 to 35 lbs

1780 to 2300

4

3925 to 5070

20.4 to 15.9 kg

35 lbs

2300 or more

5

5070 or more

15.9 kg

Flats

45 lbs

1780 or less

1

3925 or less

20.4 kg

45 to 35 lbs

1780 to 2300

2

3925 to 5070

20.4 to 15.9 kg

35 lbs

2300 or more

3

5070 or more

15.9 kg

This manual is related to the following products: