Maintenance & lubrication record – Great Plains 1006NT Operator Manual User Manual
Page 14

706/1006 Seed Box Agitator 118-903M
9/13/04
12
Great Plains Mfg., Inc.
Section 3 Maintenance & Lubrication
Maintenance & Lubrication Record
Item to be Serviced
When to Perform
Reference
Date
Problem
Solution
Uneven metering
Check for plugging in metering cup.
Check to see if seed tubes are plugged.
Reduce ground speed.
Check for lumps or trash in the material. Screen these out if needed.
Check all drive chains, sprockets, keys and pins.
The agitator will not guarantee perfect seeding of trashy, wet or sticky material.
Actual metering rate is different than
desired
Check tire pressure. Proper inflation is listed in the “Tire Inflation Chart", in the
Operator’s Manual of the 706/1006.
Check gauge wheel size.
Seed box not emptying evenly
Some sections of the box have more metering cups causing that section to run out
first.
Section 3
Maintenance & Lubrication
Section 4