Troubleshooting, Heat problems, Caution – Wheatheart Livestock Waterer User Manual
Page 21

W
HEATHEART
- L
IVESTOCK
W
ATERER
6. T
ROUBLESHOOTING
M
ODELS
: H50, H50L, EH50, EEFH50, SH50, ESH50, C50, EC50, C100, EC100, C200, EC200
IM11 R1
21
6. Troubleshooting
6.1. HEAT PROBLEMS
CAUTION
Power must be turned off at breaker box
before waterer is serviced.
WATER FREEZES IN PAN
Cause
Solution
Thermostat malfunction.
• Ensure there is power to thermostat, or if necessary,
replace thermostat.
Thermostat may not positioned prop-
erly against pan surface.
• Ensure heat-sensitive side of thermostat is completely
flush with the pan.
Faulty heating element/pad.
• Ensure element/pad is functioning. Check for power
coming into the element/pad.
Too much heat loss from inside
waterer box.
• Ensure inspection door is properly insulated and posi-
tioned and the pan is properly seated. Make sure the
base of the waterer box is sealed with weather-strip-
ping or caulking.
WATER OVER-HEATING IN PAN
Cause
Solution
Thermostat is unable to sense water/
pan temperature.
• Ensure thermostat is flush with bottom of pan surface.
Thermostat is touching the pan, but it is
still overheating.
• Replace thermostat.