4. O

PERATION

SA 1061, 1071, 1081, 1091, 1371, 1381, 1391

4.3. P

RE

-O

PERATION

30582 R7

21

4.3.2. PTO D

RIVE

Correct operation of the Wheatheart SA auger requires pre-inspection of the
drive system, operator knowledge on how to shut down the system, and a
general monitoring of the system during operation.

G

ENERAL

I

NFORMATION

Before starting the auger, ensure that:

• The PTO driveline is securely attached to the auger shaft and to the tractor.
• The PTO driveline rotating shield is in place and in good working order.
• The PTO does not exceed the maximum operating angle of 15°.
• All safety shields are in place and secure on both the tractor and the auger.
• The PTO drive on the tractor is in the off position before starting the tractor.
• The auger-to-tractor PTO hookup distances are set as specified in the decal

on the PTO shield of the auger.

• Everyone is clear of the PTO hazard area.

Note:

If shear bolt in the PTO driveline fails, shut down and lock out the tractor to
replace the bolt. Use a 5/16” x 1” GR 8 bolt. Ensure the shear point is through
the shank of the bolt, not the threads.

L

OCKOUT

1. Shut down the tractor and remove the ignition key or coil wire.
2. If step 1 is not possible, remove the PTO driveline from the tractor.

4.3.3. H

YDRAULICS

Before using the hydraulics, ensure that:

• The quick connect couplers on both the auger and the tractor are clean and

free of dirt. Wipe the couplers with a clean, dry cloth.

• The hydraulic hoses are properly connected and secured; are free of leaks,

wear, and binding; and are routed away from moving parts.

• Hydraulic pressure has been relieved prior to disconnecting.