17

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of

reach of children at a minimum height of 5 feet
(1.5 m), and away from all moving parts of door.

• NEVER permit children to operate or play with door

control push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is

properly adjusted, and there are no obstructions to door
travel.

• ALWAYS keep garage door in sight until completely

closed. NEVER permit anyone to cross path of closing
garage door.

WARNING

CAUTION

WARNING

WARNING

INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a
minimum height of 5 feet (1.5 m) where small
children cannot reach, away from moving parts of
door and door hardware. If installing into drywall, drill
5/32" holes and use the anchors provided. For
pre-wired installations (as in new home construction),
it may be mounted to a single gang box (Figure 2).

1. Strip 7/16" (11 mm) of insulation from one end of

bell wire and connect to the two screw terminals
on back of door control by color: white wire to
2 and white/red wire to the 1.

2. Remove cover by gently prying at slot in top of the

cover with a small flat head screwdriver. Fasten
with 6ABx1-1/4" self-tapping screws (drywall
installation) or 6-32x1" machine screws (into gang
box) as follows:

• Install bottom screw, allowing 1/8" (3 mm) to

protrude above wall surface.

• Position bottom of door control on screw head

and slide down to secure. Adjust screw for
snug fit.

• Drill and install top screw with care to avoid

cracking plastic housing. Do not overtighten.

• Insert top tabs and snap on cover.

3. (For standard installation only) Run bell wire up

wall and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.

4. Strip 7/16" (11 mm) of insulation from end of

bell wire. Connect bell wire to the
quick-connect terminals as follows: white to
white and white/red to red.

NOTE: When connecting multiple door
controls to the opener, twist same color wires
together. Insert wires into quick-connect holes:
white to white and red/white to red.

5. Use tacks or staples to

permanently attach
entrapment warning label
to wall near door control,
and manual release/safety
reverse test label in a
prominent location on
inside of garage door.

NOTE: DO NOT connect
power and operate opener
at this time. The trolley will
travel to the full open
position but will not return to
the close position until the
sensor beam is connected
and properly aligned.

Drywall Anchors

Insulated
Staples

Screw 6ABx1-1/4"
Control Panel (std installation)

Screw 6-32x1"
Control Panel (pre-wired)

HARDWARE SHOWN ACTUAL SIZE

Outside Keylock Accessory Connections

To opener quick-connect terminals: white to white;
white/red to red.

2-Conductor
Bell Wire

Terminal
Screws

(BACK VIEW)

Top
Mounting
Hole

Bottom
Mounting
Hole

WHITE

2

RED

1

Bell
Wire

Quick-Connect
Terminals

To release wire, push in
tab with screwdriver tip

Door Control
Connections

7/16" (11 mm)

Strip wire 7/16" (11 mm) Red

Grey

White

Lock

Light

Push
Bar

LOCK

LIGHT

LOCK

LIGHT

To Replace
Insert Top
Tabs First

STANDARD WALL MOUNT

Detector
Switch

Push Bar Cover

ON
OFF

24 Volt Bell Wire

PRE-WIRED INSTALLATION

LOCK

LIGHT

To Replace
Insert Top
Tabs First

Detector

Switch

Push Bar Cover

ON
OFF

Figure 1

Figure 2