RE PLACE MENT OF RESIN
For best quality demineralized water, replace resin as soon as existing
resin begins to exhibit an amber color. For many practical applications,
unit will continue to produce good quality demineralized water until
most of resin has changed color.
1.
Disconnect demineralizer from faucet.
2.
Remove plug from top of demineralizer.
3.
Unclamp outlet hose and turn demineralizer upside down, allowing
the exhausted resin and water to run to waste.
4.
Add more water to the column and shake the column to remove
remaining resin.
5.
Use a funnel to add the fresh resin to the column. Tap water may
be added to the resin in the funnel to facilitate filling of the
column.
6.
Continue adding resin to column until the resin bed is about 2
inches from top of column. Allow the excess water to drain from
outlet hose.
7.
Replace plug in top of column.
8.
Connect softener to faucet and proceed with normal use.
LaMOTTE COM PANY
Helping Peo ple Solve An a lyt i cal Challenges
SM
PO Box 329 • Chestertown • Mary land • 21620 • USA
800-344-3100 • 410-778-3100 (Out side U.S.A.) • Fax 410-778-6394
Visit us on the web at www.lamotte.com
61001 · 02/08