Lamotte com pany – LaMotte ALKALINITY TEST KIT AB-TAO User Manual
Page 2
PRO CE DURE
1.
Fill the graduated cylinder (0418) to the 50 mL line with sample
water. Transfer to a 125 mL Erlenmeyer flask (0431).
2.
Add one Phenolphthalein Tablet (T-2246). If the solution turns
red, P Alkalinity is present; proceed to Step 3. If the solution is
colorless, P Alkalinity is zero; proceed to Step 4.
3.
Fill buret (0427) with *Alkalinity Titration Reagent (4015). While
swirling flask, slowly add *Alkalinity Titration Reagent until red
color disappears. Record buret reading as Value P. Do not refill
buret if determining T Alkalinity.
NOTE:
If chlorine levels greater than 2 ppm are present, the
chlorine should be neutralized before testing for T Alkalinity. Use a
dechlorinating agent, such as 1 drop of 0.1N Sodium Thiosulfate
(6155).
4.
To the same flask add one BCG-MR Indicator Tablet (T-2311).
Solution will turn greenish-blue.
5.
While gently swirling flask, titrate sample with *Alkalinity
Titration Reagent until greenish-blue color changes to pink. Record
buret reading as Value T.
6.
Multiply Value P by 20. Record as ppm P Alkalinity as CaCO
3
.
Value P x 20 = P Alkalinity as ppm CaCO
3
7.
Multiply Value T by 20. Record as ppm T Alkalinity as CaCO
3
.
Value T x 20 = T Alkalinity as CaCO
3
NOTE:
Methyl Orange Indicator (2230) may be used in place of the
BCG-MR Indicator Tablets to run the test for Total Alkalinity. The
color change will be from yellow to orange-red at the endpoint.
LaMOTTE COM PANY
Helping Peo ple Solve An a lyt i cal Challenges
SM
PO Box 329 • Chestertown • Mary land • 21620 • USA
800-344-3100 • 410-778-3100 (Out side U.S.A.) • Fax 410-778-6394
Visit us on the web at www.lamotte.co
9.10