LaMotte CHLORINE DIOXIDE TEST KIT User Manual
L mott, Chlo rine di ox ide test kit
CHLO RINE DI OX IDE TEST KIT
CODE 3622
QUANTITY
CONTENTS
CODE
50
*DPD#1 Instrument Grade Tablets
*6903A-H
15 mL
Gylcine Solution
6811-E
2
Test Tube, 5 & 10 mL, w/cap
0898
1
Tablet Crusher
0175
1
Chlorine Dioxide Comparator,
0.0 - 5.0 ppm
3626
*WARNING:
Reagents marked with an * are considered to be potential health
hazards. To view or print a Material Safety Data Sheet (MSDS) for these reagents
go to www.lamotte.com. To obtain a printed copy, contact LaMotte by e-mail,
phone or fax.
To order individual reagents or test kit components, use the specified code
numbers.
PRO CE DURE
0.0 - 5.0 ppm
1.
Rinse the test tube (0898) with the sample to be tested.
2.
Pour out all but a sufficient amount of sample water to cover a tablet.
3.
Add 5 drops of Gylcine Solution (6811).
4.
Add one *DPD #1 Instrument Grade Tablet (6903A).
5.
Use the tablet crusher (0175) to crush the tablet into fine particles.
6.
Fill the tube to the 10 mL line with the sample water. Solution will
turn pink if chlorine dioxide is present.
7.
Cap and mix until the tablet disintegrates.
8.
Immediately insert the tube into the Chlorine Dioxide Comparator
(3626) and read within 30 seconds. Record the result as ppm
Chlorine Dioxide.
L Mott