beautypg.com

Phos phate in wa ter – LaMotte CORROSION CONTROL Test Kit User Manual

Page 11

background image

PHOS PHATE IN WA TER

IN TRO DUC TION

If part of your overall corrosion control program includes the addition of a
phosphate compound to inhibit corrosion in your potable water supply, a
phosphate test should be performed to measure Orthophosphate. Follow
instructions below.

QUANTITY

CONTENTS

CODE

60 mL

*Phosphate Acid Reagent

*V-6282-H

5 g

*Phosphate Reducing Reagent

*V-6283-C

2

Test Tube, 10 mL

0843

1

Spoon, measuring, 0.1 g

0699

2

Pipets, 1.0 mL, plastic

0354

1

Demineralizer Bottle

1151

1

Phosphate Comparator, 0.5 - 10 ppm

3115

*WARNING:

Reagents marked with an * are considered to be potential health

hazards. To view or print a Material Safety Data Sheet (MSDS) for these reagents
go to www.lamotte.com. To obtain a printed copy, contact LaMotte by e-mail,
phone or fax.

NOTES:
• This test determines levels of Orthophosphates only.
• This test should be run on clear samples only.
• Best results are obtained when solution temperatures are 23- 25°C.

PRO CE DURE

RANGE: 0.5 - 10 ppm Phosphate (PO

4

)

1.

Fill the test tube (0843) to the mark with the water sample.

2.

Use the 1.0 mL pipet (0354) to add 1.0 mL of *Phosphate Acid
Reagent (6282). Cap and mix.

3.

Use the 0.1 g measuring spoon (0699) to add one level measure of
*Phosphate Reducing Reagent (6283). Cap and mix until dissolved.

4.

Wait 5 minutes for the color to develop. Insert the tube into the
Comparator (3115) and compare the color to the standards to obtain
the result in ppm Phosphate.

11