Phos phate in wa ter – LaMotte CORROSION CONTROL Test Kit User Manual
Page 11
PHOS PHATE IN WA TER
IN TRO DUC TION
If part of your overall corrosion control program includes the addition of a
phosphate compound to inhibit corrosion in your potable water supply, a
phosphate test should be performed to measure Orthophosphate. Follow
instructions below.
QUANTITY
CONTENTS
CODE
60 mL
*Phosphate Acid Reagent
*V-6282-H
5 g
*Phosphate Reducing Reagent
*V-6283-C
2
Test Tube, 10 mL
0843
1
Spoon, measuring, 0.1 g
0699
2
Pipets, 1.0 mL, plastic
0354
1
Demineralizer Bottle
1151
1
Phosphate Comparator, 0.5 - 10 ppm
3115
*WARNING:
Reagents marked with an * are considered to be potential health
hazards. To view or print a Material Safety Data Sheet (MSDS) for these reagents
go to www.lamotte.com. To obtain a printed copy, contact LaMotte by e-mail,
phone or fax.
NOTES:
• This test determines levels of Orthophosphates only.
• This test should be run on clear samples only.
• Best results are obtained when solution temperatures are 23- 25°C.
PRO CE DURE
RANGE: 0.5 - 10 ppm Phosphate (PO
4
)
1.
Fill the test tube (0843) to the mark with the water sample.
2.
Use the 1.0 mL pipet (0354) to add 1.0 mL of *Phosphate Acid
Reagent (6282). Cap and mix.
3.
Use the 0.1 g measuring spoon (0699) to add one level measure of
*Phosphate Reducing Reagent (6283). Cap and mix until dissolved.
4.
Wait 5 minutes for the color to develop. Insert the tube into the
Comparator (3115) and compare the color to the standards to obtain
the result in ppm Phosphate.
11