ORDERING INFORMATION
•
AL-48061 Positioner Controller, 6 Axis
•
AL-48062 Positioner Controller,
6 Axis w/Built-In PCU, 1 HP
•
AL-48063 Positioner Controller,
6 Axis w/Built-In PCU, 2 HP
front panel
>
Controls:
AC Power On/Off
Axis Select
- Operating Axis
- Display Axis
Direction/Speed
- Coarse & Fine
Position Offset
Position Zero
Remote/Local Control (BUS/PANEL)
Emergency Stop (E-Stop)
>
Displays & Indicators:
Axis Position
- Operating Axis
- Display Axis
Axis Number
- Operating Axis
- Display Axis
Limit Indicators
User-Selectable Scales: ± 180°, 0°-360°, Linear
Remote/Local
Speed (Operating Axis)
technical notes
AL-48061 and AL-48062 are functionally compatible with
previous generation models AL-4806-3A & AL-4806-3A
Opt. 1, respectively, with limitations and enhancements
(consult your local factory sales representative for
specifi c compatibility needs).
position sensors
>
Axis-Independent Position Sensor Selection:
Single-Speed, Dual-Speed Synchro & Incremental Encoder
Absolute Encoder (EnDat
®
), Inclinometer & Inductosyn
®
(Refer to Options List)
communication & i/o
IEEE-488.2 Compatible
RS-232 (RJ45)
TTL Position Increment
BCD/Binary Position Output
supplied accessories
>
CD-ROM Documentation Set:
User Manual (Installation, Setup, Operation)
Programming Reference Manual
Software Setup Utility
>
Cables:
Cable, CAN, DB9 to RJ45 (for Setup Utility)
Cable, RS-232, DB9 to RJ45 (for Setup Utility)
AC Power Cord, IEC-320 (F) to Plug
options
Opt. 003 - Inductosyn
®
Interface
Opt. 004 - Inclinometer Interface
Opt. 005 - EnDat
®
Absolute Optical Encoder
Interface
Opt. 007 - 400 Hz Synchro Support
(Includes External 400 Hz Generator)
Opt. 008 - 11.8 Volt Synchro Input
(Requires Opt. 007)
Opt. 009 - Correction Table Capability
(On-site error mapping purchased separately)
Opt. 101 - Additional Manual Set
Opt. 102 - International Localization
(Specify Country & Voltage)
Optional
Standard