T-DualScan is an innovative planar near-field system that offers the best compromise between
accuracy, flexibility and measurement speed. The tower positioner can rotate 180° to switch easily
from the single-probe set-up (0.8 - 110 GHz) to the multi-probe set-up (0.8 - 18 GHz). T-DualScan
can also be offered as an upgrade to existing installations.
Technology
•
Near-field / Planar
•
Near-field / Cylindrical
Measurement capabilities
•
Gain
•
Directivity
•
Beamwidth
•
Cross polar discrimination
•
Sidelobe levels
•
3D radiation pattern
•
Radiation pattern in any polarization (linear or circular)
•
Antenna efficiency
•
Beam pointing properties
Frequency bands
•
Single-probe: 800 MHz - 110 GHz
•
Multi-probe: 800 MHz - 18 GHz
•
Multi-probe: 70 - 800 MHz on request
Scan area
•
Multi-probe: up to 12 m Y axis (1 m module)
•
Single-probe: up to 15 m Y axis (1 m module)
•
X-axis length depends on customer requirement
Probe array oversampling capability
•
Movement of the probe array on the vertical axis
Software
Measurement control, data acquisition and post processing
■
MiDAS
SatEnv
959 Spectrum (North America only)
Equipment
■
Amplification unit
■
Mixer unit
■
N-PAC
■
Primary synthesizer
■
Auxiliary synthesizer
■
Transfer switching unit
■
Power and control unit
■
Probe array power supply
■
Heavy DUT positioner
■
Elevation positioner for gantry arm
■
Positioner controller**
■
E-Stop unit
■
Local control unit**
■
Real time controller**
■
Control interface unit
■
Uninterruptible power supply
■
Instrumentation rack
■
Ethernet switch
AUT Port switch
Add on
■
Calibration kit (arm, reference antenna, positioner and interface)
Laser alignment instrumentation (laser inclinometer, laser tracker,
spin diode laser, laser pointer, digital spirit level and dial-indicator)
Absorbers*
Shielded anechoic chambers*
Accessories
Reference antennas (horns, standard gain horns, etc.)****
Probes****
Services
■
Installation and calibration
■
Warranty
■
Training
■
Project management
Post warranty service plans*****
MV-Cor
TM
correction table service***
* See AEMI/ Rainford EMC
Included
Optional
Required
Systems catalogs for more information
** See ORBIT/FR positioning equipment catalog for more information
*** See MV-CorTM service sheet for more information
**** See SATIMO & ORBIT/FR antenna catalog for more information
***** Refer to Orbit/FR service brochure for more information
System configurations
Main features
Easily switch from a single probe
to a multi-probe set-up
SOLUTION FOR
• Antenna Measurement
• Pulsed Measurement
• Phased Array Antenna Measurement
+
I T-DualScan