9.0 REPAIRS
9.1 If the heater malfunctions, and is no longer
operating, send the heater to the factory for
servicing. Do not attempt to service the unit.
9.2 When returning the heater you can fill out the
online repair form at http://www.ccithermal.com/
online-repair-form.php or include the following
information with the heater when shipping:
• Company name and address
• Contact name
• Telephone/fax number/email
• Product model and serial numbers
• Tagging codes
• Advise if an estimate is required prior to
starting the repair
• P.O. Number
• Description of problem(s) and/or
required repairs
• Special instructions (if applicable)
• Return shipping instructions
10.0 TROUBLESHOOTING
WARNING
ONLY OPEN THE JUNCTION BOX IF IT IS SAFE
TO DO SO!
10.1 These heaters contain a thermal fuse. If the
unit is not operating within proper constraints,
the unit may have overheated, causing the
thermal fuse to open. Check the thermal fuse by
disconnecting the power, opening the junction
box and measuring the resistance across the
terminals. If the resistance is infinite, the fuse
has been triggered and the unit must be sent to
CCI Thermal Technologies Inc. for repair.
NOTE: If your circuit contains a thermostat and the
ambient temperature is high enough to turn off the
thermostat, the measured resistance will be infinite,
this test will not check the thermal fuse.