SS95 SURGE OPERATION / MAINTENANCE MANUAL
PAGE 3
1 INSTALLATION
1.1 UNPACKING
After unpacking, the Surge Suppressor should be checked for any damage that
may have occurred during shipment. Damage should be reported to the carrier
immediately.
The following items should be included within the shipping container:
Qty
Item
Description
1
SS95
SS95 Surge Suppressor
1 MSS95
Operation/Maintenance
Manual
1 **
Seal,
Port
**Dependent upon type of pump option selected.
1.2 LOCATING / MOUNTING SURGE
• Remove port plug from pump.
• Install new port seal.
• Hand tighten surge suppressor into port. Do not over tighten.
ATTENTION: Over-tightening adapter into pump will result in pump damage.
• Run 1/8 bleed line to drain. In the event of a diaphragm failure fluid may flow
through tube to drain.
• Connect air supply using 3/8” or larger air line. Air supply to Surge
Suppressor must be equal to or greater than pump supply pressure.
NOTE: When connecting the SS95 to an externally controlled pump, do not
connect the SS95 air supply via a tee from the pump. Connect to a separate
continuous supply.