beautypg.com

Installation, Unpacking, Tie bolt torque – Trebor 120D Mega User Manual

Page 3: Utilities / hook-up, 1installation

background image

MEGA 120D PUMP OPERATION / MAINTENANCE MANUAL

PAGE 3

1

INSTALLATION

1.1 UNPACKING

After unpacking, the pump should be checked for any damage that may have occurred
during shipment. Damage should be reported to the carrier immediately.

The following items should be included within the shipping container:

Qty

Item

Description

1

120D

Mega 120D Pump

1

M120D

Operation/Maintenance Manual

1.2 TIE BOLT TORQUE

The tie bolts on the pump are tightened before leaving the factory. However, relaxation
may occur due to handling, material creep, or other unforeseen events. Trebor
recommends that all eight tie bolts be re-tightened upon pump install. The following
procedure should be used:

1. Remove black tie bolt caps (Item 17 in Figure 4-1) from both sides of all 8 tie

bolts

2. Apply 80 in-lbs. (9.0 N-m) of torque to each slave side bolt while holding the

master side bolt stationary. A star-pattern is advised.

a. The master side is the left side of the pump if you are looking at the fluid

ports.

3. Replace the tie bolt caps.

1.3 UTILITIES / HOOK-UP

The pump is mounted using four 1/4” bolts. It is recommended that the pump be
mounted not more than 15

from level to maintain self-priming ability and pumping

efficiency.

Air Inlet:

1/2” FNPT (3/8” Dia. [8mm] supply tube minimum).

Air Supply:

25-80 psig (0.17-0.55 MPa) clean dry air or nitrogen. (For Air
Consumption, See Section 3.1 Performance Charts)

Fluid Ports: Inlet/Outlet Fluid Fittings and Surge Suppressor require tightening to

specified torque values during pump installation. See Section 2 for
installation diagram and torque values.