TerraLUX Decorative MR16 LED Lamp Product Specification (04/01/2013) - Subject to change without notice
3
www.terraluxillumination.com
TESTS AND CERTIFICATIONS
Product Safety Certifications
UL Standard 1993: Self Ballasted Lamps and Lamp Adaptors
UL Standard 8750: LED Light Sources for Use In Lighting Products
CSA C22.2 No. 1993-09: Self Ballasted Lamps and Lamp Adaptors
Radio Frequency Emissions
FCC Part 15, Unintentional Radiators Class B.
Sec 107, Conducted Emissions - 0.15MHz – 30MHz
Industry Canada Notice ICES-003: Class B Digital Apparatus
Reduction of Hazardous Substances
(RoHS)
European Council Directive 2002/95/EC, (including amendments 2005/618/EC,
2005/717/EC and 2005/747/EC) on the restriction of certain hazardous substances in
electrical and electronic equipment.
Electro-Static Discharge
IEC 61000-4-2: 2001-04 Electromagnetic Compatibility (EMC) - Part 4: Testing and
measurement Techniques - Section 2: Electrostatic Discharge (ESD) Immunity Test.
± 2kV and ± 4kV contact discharge to all exposed conductive (25 discharg-
es each polarity)
±6kV and ± 8kV air gap discharges to all non-conductive surfaces (25 dis-
charges each polarity)
Power Factor
0.67 @ 12 V AC/60Hz
Shock
Operating - 82 G peak, 2 ms; Half sine, 1 shock per second 20 shocks per axis, both di-
rections – total 120 shocks
Non-Operating - 120 G peak., 2 ms, Half sine, 1 shock/second, 3 shocks per axis, both
directions – total of 18 shocks
40 G Faired Square wave w/ velocity change of 62 in/sec. 1 shock per axis, both direc-
tions – total of 6 shocks
Vibration
Operating - Random PSD Spectrum G, 1.0G RMS, 10-2000 Hz. 30 minutes per axis 3-500
Hz., 0.50 g peak, swept sine @ ½ octave/min per axis
Non-Operating - Random PSD, 5 G RMS, 15 minutes per axis
5-500-5 Hz, 1.0 g peak, Swept Sine @ ½ Octave per minute, per axis.
Shipping / Transit
International Safe Transit Association (ISTA) Project 2A.
Packaging details:
11” x 4.5” x 3”, 1 layer, 10 units/box, weight = 1lbs 8oz
Operating Temperature
-40°C to +55°C, 0 to 95% R.H. / 153 hr.
Storage Temperature
-40°C to +85°C / 60 hr. followed by 20°C to 85°C, 5 to 95% R.H. / 80 hr.
Long Term Operation
100 samples of the TLL-R16A operated continuously for a cumulative operating runtime
equal to two times the 3 year warranty period, or 52,560 Hrs. During this test, a nominal
12Vac supply voltage was applied, and the samples were tested in a lab ambient tem-
perature environment.
Input Voltage Range
9.6—14.4 V AC/DC