TERRALUX SR8 Install User Manual
Page 2

TerraLUX Inc.
Document P/N 025000085B
1-866-498-1564
www.terralux.com
9.
REMOVE ORANGE CONNECTOR PLUG FROM MATING ORANGE RECEPTACTACLE LOCATED ON
BOTTOM OF WHITE LED DRIVER MODULE.
10. FIRMLY PRESS THE BLACK OR BLUE WIRE HARNESS WIRE INTO THE ‘B” SLOT OF THE CONNECTOR
PLUG. FIRMLY PRESS THE WHITE WIRE HARNESS WIRE INTO ADJACENT CONNECTOR SLOT.
TUG ON
BOTH WIRES TO ENSURE THEY ARE LOCKED INTO THE CONNECTOR.
11. CONNECT WIRE HARNESS LEADS TO MAINS WIRING INSIDE JUNCTION BOX USING (3) WIRE NUTS:
WIRING CONNECTION DETAILS:
a.
GREEN/YELLOW WIRE TO GROUND WIRE (BARE OR GREEN)
b.
BLACK OR BLUE WIRE TO LINE CONDUCTOR (BLACK)
c.
WHITE WIRE TO NEUTRAL CONDUCTOR (WHITE)
12. REATTACH FIXTURE TO JUNCTION BOX USING EXISTING FIXTURE MOUNTING SCREWS, OR
THREADED MOUNTING TUBE, DO NOT TIGHTEN.
13. ATTACH THE ROUND LED MOUNTING PLATE TO THE FIXTURE MOUNTING SCREWS FROM THE
JUNCTION BOX. TIGHTEN SCREWS.
14. ATTACH THE SPADE CONNECTOR END OF THE GREEN/YELLOW WIRE TO THE ROUND LED
MOUNTING PLATE USING THE PRE-INSTALLED GREEN GROUNDING SCREW.
15. CONNECT THE ORANGE WIRE HARNESS CONNECTOR TO THE MATING ORANGE RECEPTACLE ON
THE BOTTOM OF THE LED DRIVER MODULE.
16. CONNECT THE SMALL WHITE CONNECTOR FROM THE LED DRIVER MODULE TO THE RING OF LEDS
ON THE ROUND LED MOUNTING PLATE. ALIGN UNLOCK SYMBOL ON PLATE TO FEATURE ON
DRIVER. SECURE DRIVER MODULE TO THE ROUND LED MOUNTING PLATE BY ROTATING TO LOCK
SYMBOL POSITION.
NOTE: THE WIRE HARNESS MUST NOT BE EXPOSED AFTER COMPLETING THE RETROFIT, AND NOT
CONTAIN ANY SPLICE UNDER THE DRIVER MODULE. WIRES SHOULD NOT BE PINCHED BETWEEN
FIXTURE OR DRIVER OR PLATE.
17. REATTACH DIFFUSOR/GLOBE
18. TURN POWER BACK ON AT THE BREAKER PANEL AND VERIFY OPERATION
Use Round LED Plate as
template for Proper Wire Hole
Placement
Hole is Opposite Lock-
Unlock Symbol
Wires Harness Routed Through
Grommet and Fixture.
Small Connector to LEDs
Align Driver to “Un-Lock” Symbol
Rotate Driver to “Lock”
Symbol