DIP Switches
DIP Switch Settings
The DIP switches are found on the left hand side of the 326.
N
N
Zone C1
Zone C2
65
66
67
68
Pump
Pump
tN4
Meets Class B: Canadian
ICES & FCC Part 15
Made in Canada
10 A (max)
Zone Expansion Module 326
tektra 999-01
Relay Rating: 115 V (ac) 5 A
N
Zone C3
69
70
Pump
N
Zone Group
71
72
Pmp C
Power
Zone Group Pump C
Zone C1
Zone C2
Zone C3
51
52
53
54
55
56
57
58
59
60
61
62
C
C
W
W
R
R
tN4
tN4
C
W
R
tN4
tNt
Zone C1
tNt
Zone C2
tNt
Zone C3
63 64
C
tN4
Zn Grp C
C1
C2
On/Off
Zone Group
Pump C
C3
Limited power available, see wiring brochure
H7002B
C1
C2
On/Off
Zone Group
Pump C
C3
Zone Group Pump
Each zone has a corresponding Zone Group Pump DIP
switch.
Zone Group Pump DIP switch set to On:
•
• The Zone Group Pump turns on when the zone calls for
heat.
Zone Group Pump DIP switch set to Off:
•
• The Zone Group Pump does not turn on when the zone
calls for heat.
LED Status Indicators
Zone Expansion Module 326
Power
Zone Group Pump C
Zone C1
Zone C1
Zone C1
Power LED
Green:
•
• Normal operation.
Off:
•
• No power to the Zone Expansion Module.
Zone LEDs
Green:
•
• The zone is on.
Off:
•
• The zone is off.
Zone Group Pump LED
Green:
•
• The Zone Group Pump relay is on.
Off:
•
• The Zone Group Pump relay is off.
Five LEDs to provide the status of the 326’s outputs.
Cleaning the Control
The control’s exterior can be cleaned using a damp cloth. Moisten the cloth with water and wring out prior to wiping the
control. Do not use solvents or cleaning solutions.