Handbook for the SXVR-H16

Issue 1 June 2009

4

‘update driver’. Following the on screen instructions will allow you to re-select the
correct inf file (SXVIO_H16_126.inf) and driver files (SXVIO.sys and generic.sys),
which should fix the problem.

Now connect up the power supply and switch it on. The supply is a very efficient
‘switch mode’ unit, which can operate from either 110v or 220v AC via an
appropriate mains power cable (supplied). You can now start the ‘SXV_hmf_usb’
software by double clicking on the icon when you should see the main menu and
image panel appear. If this is the first time that it has been run, you will receive a
warning about the lack of an ‘ini’ file – just click on ‘OK’ and then open ‘Set program
defaults’ from the ‘File’ menu. In the bottom right hand corner of this box, select
SXV-H16. You can now set up the camera control defaults (shown below), as
follows:

1) Background Image area

Red (or as preferred)

2) FITS Unsigned Integer format

Off

3) Star mask size (area used for photometry and guiding)

8 pixels

4) Telescope guiding output to ‘autoguider socket’

The other default settings are not important for current purposes and may be left as
the software start-up values for now. Now click on ‘Save’ and the ini file will be
created and the software set for your camera.